Add On Residual Current Devices (RCD) for Miniature Circuit Breakers up to 63A
Discover the Acti 9 Vigi iC60 add-on RCD for iC60 Miniature Circuit Breakers
Benefits
- The absolute safety for earth leakage protection in final distribution
- Greater continuity of service with VisiTrip
- Greater electrical immunity with Si type (Super immune),
- Simple to choose with meaningful part numbers,
- Easy to install with robust terminal connections
- Environmentally friendly with 100% recyclable & recoverable materials.
Applications
Protection in all industrial and commercial buildings against :
- Electrocution in accordance with installation standard IEC 60364 and national standards
- The risk of fire due to current leakage into building materials
Features
The simplicity of combining Vigi iC60 DIN rail add-on RCDs with iC60 MCBs makes them extremely easy to install.
- Class-2 insulation : continuous safety for operators and unqualified personnel.
- VISI-TRIP : detects faulty outgoers quickly and reduces intervention time.
- Fully immune earth leakage protection : better continuity of service, especially with the new Si type (Super immune) in polluted environments and networks.
- Electrically and mechanically connected to iC60 Miniature Circuit-Breakers (MCBs),
- Nominal current: 25 to 63 A
- Si (Super immune), AC, A types,
- 30mA sensitivity: additional protection against direct contact (in accordance with IEC 60364)
- 100mA, 300mA, 500mA and 1000mA sensitivities: additional protection against fire and indirect contact (in accordance with IEC 60364)
- Si type (Super immune): protection of sensitive circuits (computing equipment) and those prone to disturbances (light fittings with electronic ballast, power electronics)
- Selective version : to ensure correct discrimination between different Residual Current Devices (RCDs) and the tripping of the device closest to the fault
- Compliance with standard IEC EN 61009-1, certified by national official authorities
- The DIN rail iC60 Miniature Circuit-Breaker (MCB) retains the same characteristics when combined with a Vigi iC60 DIN rail add-on Residual Current Device (RCD).
- For more information click here
Acti 9 Vigi for iC60 Product Range
Vigi iC60 add-on residual current devices for 230/400 V network | ||||
Current Rating | Sensitivity | 2 Poles![]() |
3 Poles![]() |
4 Poles![]() |
25A | 10mA | A9V10225 | – | – |
30mA | A9V41225 | A9V41325 | A9V41425 | |
100mA | A9V12225 | A9V12425 | ||
300mA | A9V44225 | A9V44325 | A9V44425 | |
500mA | A9V16225 | A9V16325 | A9V16425 | |
40A | 10mA | – | – | – |
30mA | A9V41240 | A9V41340 | A9V41440 | |
100mA | – | – | — | |
300mA | A9V44240 | A9V44340 | A9V44440 | |
500mA | A9V16240 | A9V16340 | A9V16440 | |
63A | 10mA | – | – | – |
30mA | A9V41263 | A9V41363 | A9V41463 | |
100mA | A9V12263 | – | A9V12463 | |
300mA | A9V44263 | A9V44363 | A9V44463 | |
500mA | A9V16263 | A9V16363 | A9V16463 |