Acti 9 iID2019-02-05T17:59:54+00:00

DIN Rail Residual current circuit breakers (RCCB) up to 100 A

In coordination with Acti 9 and Multi 9 MCBs, this RCCB will also give you additional protection against any direct contact

Benefits

Complete with VisiTrip and Visi-SAFE, the DIN rail RCCB provide greater continuity of service as well as enhanced protection to both industrial and commercial buildings.

  • Greater continuity of service with VisiTrip.
  • Greater electrical immunity with SI type (Super immune).
  • Easy-to-understand part numbers make choosing options simple and straightforward.
  • Easy to install with quick, ergonomic and secure IP20B terminal shutters.
  • Fully robust connections which provide twice the standard tightening torque.
  • Environmentally friendly: made from 100% recyclable and recoverable materials.

Applications

  • Designed for industrial and commercial buildings
  • Prevent electrocution (in accordance with installation standard IEC 60364 and national standards).
  • Reduce fire hazards by cutting down current leakage into building electrical installations.

Features

Achieve full coordination with Acti 9 and Multi 9 MCBs with DIN rail RCCB you can rely on. Providing better continuity of service as well as offering a complete environmentally friendly option, the DIN rail RCCB will also give you additional protection against any direct contact.

  • Complete with VISI-SAFE, which helps to ensure the ultimate in safety for both operation and maintenance work.
  • Class-2 insulation: ensures continuous protection for both operators and unqualified personnel.
  • Complete with VisiTrip: detects faulty outgoers quickly and reduces intervention time.
  • Fully immune earth leakage protection: provides better continuity of service, especially with the new SI type (Super immune) which has been designed with polluted environments and networks in mind.
  • The optional electrical auxiliaries and mounting accessories are consistent with those offered on Acti 9 iC60 miniature circuit breakers (MCBs).
  • Nominal current: 1 to 100 A.
  • SI (Super immune), AC, A.
  • 30 mA sensitivity: provides additional protection against direct contact (in accordance with IEC 60364).
  • 100 mA, 300 mA, 500 mA sensitivities: provide additional protection against fire and indirect contact (in accordance with IEC 60364).
  • Selective version: ensures correct discrimination between different residual current circuit breakers as well as the tripping of the device closest to the fault.
  • Coordination with Acti 9 and Multi 9 MCBs.
  • Fully compliant with standard IEC EN 61008-1.
  • Certified by national official authorities.
  • Ideally suited to isolation in full accordance with industrial standard IEC/EN 60947-2.
  • Operating voltage: up to 400 VAC.
  • Insulation voltage: 500 V.
  • Optional auxiliaries available: an indication of state and tripping, shunt tripping, Undervoltage tripping, overvoltage tripping.

Acti 9 iID Product Range

AC type

iID residual current circuit breakers for 230/400 V network
Type AC 
Current Rating Sensitivity 2 Poles 4 Poles
       
16A 10mA A9R10216
 
25A 10mA A9R10225
30mA A9R71225 A9R71425
300mA A9R74225 A9R74425
500mA A9R16225 A9R16425
 
40A 30mA A9R71240 A9R71440
100mA A9R12240 A9R12440
300mA A9R74240 A9R74440
500mA A9R16240 A9R16440
 
63A 30mA A9R71263 A9R71463
100mA A9R12263 A9R12463
300mA A9R74263 A9R74463
500mA A9R16263 A9R16463
 
80A 30mA A9R11280 A9R11480
100mA A9R12280 A9R12480
300mA A9R14280 A9R14480
500mA A9R16480
 
100A 30mA A9R11291 A9R11491
100mA A9R12291 A9R12491
300mA A9R14291 A9R14491
 
Voltage rating (Ue) 230 – 240 V 400 – 415 V
 
Operating frequency 50/60 Hz

A type

iID residual current circuit breakers for 230/400 V network
Type A 
Current Rating Sensitivity 2 Poles 4 Poles
       
16A 10mA A9R20216
 
25A 10mA A9R20225
30mA A9R51225 A9R51425
300mA A9R54225 A9R54425
 
40A 30mA A9R51240 A9R51440
100mA A9R22440
300mA A9R54240 A9R54440
500mA A9R26440
 
63A 30mA A9R51263 A9R51463
100mA A9R22463
300mA A9R54263 A9R54463
500mA A9R26463
 
 80A
30mA A9R21480
300mA A9R24480
 
100A 30mA A9R21291 A9R21491
300mA A9R24291 A9R24491
  500mA A9R26491
 
Voltage rating (Ue) 230 – 240 V 400 – 415 V
 
Operating frequency 50/60 Hz